The USB screen stays black
- 3 min
- Windows 10 and 11
- Cube Controls CSX-3, Ascher, VoCore screens
Answer one question at a time. The page keeps your answers above and stops on the cause and what to do.
- In Windows' Device Manager, does the screen show a yellow triangle (code 28)?Answer:
- The driver is missing. Install WinUSB with Zadig, on the C872 1004 entry only.Install the driver, step by step
- Does the screen show up on SimLogix's Devices page?Answer:
- Does its page, or its card, say "Its screen isn't known to SimLogix yet." or "Not known yet"?Answer:
- SimLogix doesn't know its panel yet and doesn't guess its size. Survey it: "Survey it", two minutes. We add the screen, and it works on the next launch.A screen SimLogix doesn't know yet
- Another program is holding the screen: two programs can't hold it at once. Close it, replug the wheel, restart SimLogix.
- In Devices, this screen, Screen tab: is “On” on?Answer:
- Turn “On” on: off, SimLogix sends it nothing.
- On the Dashboard page, under the preview, does this screen say it shows a dashboard?Answer:
- Nothing is sent to it. Launch a dashboard to it: Dashboard, this screen at the top of the page, a dashboard, then “Put on” the screen. Or, from the home page, roll out a config that holds this screen.Launch a dashboard
- Has your game been closed for several minutes, with a config running?Answer:
- That's your config's sleep: the screen comes back when the game starts. The delay is set in the config, step Between sessions.
- Did the picture freeze, or drop out along the way?Answer:
- The screen dropped out after a USB drop, from a hub or a cable. Unplug the cable, wait ten seconds, plug it back in. Use a port at the back of the PC, without a hub: on a front port, a CSX-3 can freeze after a few seconds.
- Ask on Discord, with a screenshot of Device Manager, one of the Devices page, your SimLogix version and the log.Report a problem
Why a driver
Section titled “Why a driver”These screens are not monitors: Windows doesn’t know they exist. They receive images over USB, through a generic driver, WinUSB, that you bind once with Zadig. SimLogix never touches drivers itself: you know what changed on your machine, and how to undo it.
A choppy picture rather than a black one? Two screens behind one hub, or a “full-speed” link: the Devices page flags it. Plug each screen into a different group of ports, at the back of the PC.